Square D Shunt Trip Breaker Wiring Diagram

A Square D shunt trip breaker is a safety device that shuts off electrical power to a circuit in the event of an emergency. It is commonly used in commercial and industrial settings where safety is of utmost importance. Installing a shunt trip breaker requires proper wiring to ensure it functions correctly. This article will provide a comprehensive guide to wiring a Square D shunt trip breaker.

What is a Shunt Trip Breaker?

A shunt trip breaker is a type of circuit breaker that trips open a circuit when it receives a signal from an external source. It is commonly used in buildings with elevators or large machinery that require an emergency shut-off in case of a malfunction. A shunt trip breaker can be triggered through a manual switch or a remote control signal.

The shunt trip mechanism is essentially a small solenoid that when powered, activates a spring-loaded latch which, in turn, trips the breaker. This mechanism is built into the breaker and is designed to operate quickly and reliably in case of a power outage or other emergency.

How Does a Shunt Trip Breaker Work?

The shunt trip mechanism works by energizing a solenoid coil. When energized, the solenoid pulls in a plunger, which releases the latch that holds the breaker closed. The spring-loaded mechanism inside the breaker then forces the contacts open, breaking the circuit and shutting off the power.

The solenoid coil can be activated in one of two ways. The first is by manually flipping a switch, which sends power to the solenoid coil. The second is by sending a remote control signal to a relay, which in turn sends power to the solenoid coil. In either case, the solenoid is energized, and the circuit breaker trips open.

Wiring a Square D Shunt Trip Breaker

Before wiring a shunt trip breaker, it is important to understand the wiring diagram for the specific breaker being installed. Square D shunt trip breakers are available in different ampere ratings and can be wired in different ways depending on the application.

For example, a 50-amp shunt trip breaker may have different wiring requirements than a 30-amp shunt trip breaker. The wiring diagram for each breaker will be listed on the packaging or available from the manufacturer’s website.

The basic wiring diagram for a Square D shunt trip breaker is as follows:

Wire Color Function
Red Remote Control Switch Input
White Neutral
Black Line (Hot)
Green Ground

The red wire is connected to the remote control switch, which is used to trigger the shunt trip mechanism. The white wire is connected to the neutral bus bar, while the black wire is connected to the line (hot) bus bar. The green wire is connected to the ground bus bar.

It is important to note that the wiring diagram may vary depending on the specific breaker being installed. Always consult the manufacturer’s instructions before wiring a shunt trip breaker.

FAQ

What is the purpose of a shunt trip breaker?

A shunt trip breaker is used to provide an emergency shut-off in case of a malfunction. It is commonly used in buildings with elevators or large machinery that require a quick and reliable shut-off mechanism.

What is a remote control switch for a shunt trip breaker?

A remote control switch is used to trigger the shunt trip mechanism in a breaker. It can be located near the machinery or equipment being controlled, or it can be installed in a control room away from the machinery.

Can a shunt trip breaker be manually tripped?

Yes, a shunt trip breaker can be manually tripped by flipping a switch on the breaker. This can be useful in situations where it is necessary to shut off power to a circuit quickly.

What is the difference between a shunt trip breaker and a standard circuit breaker?

A shunt trip breaker is designed to trip open in case of an emergency or malfunction. It has a built-in mechanism that allows it to be triggered remotely or manually. A standard circuit breaker is designed to trip open in case of an overload or short circuit.

When should a shunt trip breaker be used?

A shunt trip breaker should be used in commercial or industrial settings where safety is a top priority. It is commonly used in buildings with elevators or large machinery that require an emergency shut-off in case of a malfunction.

In conclusion, wiring a Square D shunt trip breaker requires careful attention to the manufacturer’s instructions and the specific ampere rating of the breaker being installed. Always consult with a qualified electrician if you are unsure about the correct way to wire a shunt trip breaker. With proper installation and maintenance, a shunt trip breaker can provide reliable and efficient emergency shut-off protection for your building or machinery.