Walk In Cooler Defrost Timer Wiring Diagram

Walk-in coolers are essential for maintaining the freshness of food items in various food service settings, such as restaurants, cafes, and supermarkets. One of the important components of a walk-in cooler is the defrost timer. It helps in preventing the buildup of frost on the evaporator coils, which can lead to various problems, such as reduced cooling efficiency, increased energy consumption, and even equipment failure. In this article, we will discuss the wiring diagram of a walk-in cooler defrost timer in detail.

Defrost Timer Function

A defrost timer is an electromechanical device that controls the duration and frequency of the defrost cycle of a refrigeration system. The defrost cycle is necessary to remove the frost buildup on the evaporator coils, which occurs due to the continuous cooling of the air inside the walk-in cooler. The defrost timer turns off the compressor and turns on the defrost heaters or hot gas bypass valve to melt the frost on the coils. Once the defrost cycle is completed, the timer switches back the system to the cooling mode.

Generally, there are two types of defrost timers used in walk-in coolers: mechanical and electronic. The mechanical defrost timer comprises a motor-driven clock mechanism that rotates a dial with pins or trippers attached to it. The pins or trippers are set to activate the defrost cycle at specific intervals, such as every 6, 12, or 24 hours, depending on the requirement. The electronic defrost timer, on the other hand, uses a microprocessor-based control board to monitor the system parameters, such as temperature and humidity, and adjust the defrost cycle accordingly.

Wiring Diagram

The wiring diagram of a walk-in cooler defrost timer consists of several components, such as power supply, defrost termination switch, defrost heater, compressor, and fan motor. The diagram shows the connection between these components and the defrost timer through various wires and terminals. Let’s discuss each component and its wiring in detail.

Power Supply

The power supply is the source of electrical energy that drives the walk-in cooler refrigeration system. It is usually a single-phase or three-phase AC voltage, depending on the rating of the compressor and other components. The power supply is connected to the L1 and L2 terminals of the defrost timer through a cable or conduit. The L1 terminal carries the line or hot wire, while the L2 terminal carries the neutral or return wire.

Defrost Termination Switch

The defrost termination switch is a temperature sensor or timer that signals the defrost timer to end the defrost cycle and resume the cooling cycle. It is usually located on the evaporator coil or nearby, where it can sense the temperature of the coil. In case of a temperature sensor, the switch is wired in series with the defrost heater, such that when the temperature rises above a preset value, the switch opens and shuts off the heater. In case of a timer, the switch is wired in parallel with the defrost heater, such that when the set time elapses, the switch closes and completes the circuit for the heater. The defrost termination switch is connected to the T1 and T2 terminals of the defrost timer.

Defrost Heater

The defrost heater is a resistance heating element that generates heat to melt the frost on the evaporator coil. It is usually a high-wattage wire or rod that is wrapped around the coil or inserted into it. The defrost heater is energized by the defrost timer during the defrost cycle and deactivated by the defrost termination switch when the frost is melted. The defrost heater is connected to the H1 and H2 terminals of the defrost timer.

Compressor

The compressor is the heart of the refrigeration system, which compresses the refrigerant gas and pumps it into the condenser coil. The compressor is wired in series with the defrost timer and the thermostat, such that when the cooling cycle is on, the defrost timer is bypassed and the compressor runs continuously until the set temperature is reached. When the set temperature is reached, the thermostat signals the defrost timer to start the defrost cycle, and the compressor is turned off. The compressor is connected to the C and S terminals of the defrost timer.

Fan Motor

The fan motor is responsible for circulating the air inside the walk-in cooler, which helps in maintaining a uniform temperature and humidity. The fan motor is wired in parallel with the compressor, such that when the cooling cycle is on, the fan motor runs continuously. When the defrost cycle starts, the fan motor is turned off to prevent the circulation of hot air inside the cooler. The fan motor is connected to the F1 and F2 terminals of the defrost timer.

FAQs

Question Answer
What is a defrost timer? A defrost timer is an electromechanical device that controls the duration and frequency of the defrost cycle of a refrigeration system.
Why is a defrost cycle necessary? A defrost cycle is necessary to remove the frost buildup on the evaporator coils, which occurs due to the continuous cooling of the air inside the walk-in cooler.
What are the types of defrost timers? The two types of defrost timers are mechanical and electronic.
What is a defrost termination switch? A defrost termination switch is a temperature sensor or timer that signals the defrost timer to end the defrost cycle and resume the cooling cycle.
What is a defrost heater? A defrost heater is a resistance heating element that generates heat to melt the frost on the evaporator coil.

Conclusion

The wiring diagram of a walk-in cooler defrost timer is crucial for ensuring the proper functioning and efficiency of the refrigeration system. By understanding the connection between the various components and the defrost timer, one can troubleshoot the system in case of any malfunction or damage. It is important to follow the wiring diagram carefully and use the appropriate wires and terminals to avoid any electrical hazards or equipment damage.