Bodine BSL17C C2 Wiring Diagram

If you’re looking for a reliable emergency lighting solution, the Bodine BSL17C C2 is an excellent choice. This unit is designed to provide up to 90 minutes of emergency lighting in the event of a power outage, making it ideal for use in commercial buildings, schools, and other public spaces. To ensure that your Bodine BSL17C C2 is wired correctly, it’s important to follow the wiring diagram provided by the manufacturer. In this article, we’ll provide a detailed guide to wiring your Bodine BSL17C C2, and answer some frequently asked questions about this unit.

Wiring the Bodine BSL17C C2

The Bodine BSL17C C2 is designed to be wired in a specific way to ensure that it will function as intended in an emergency situation. The wiring diagram provided by the manufacturer should be followed closely to ensure proper installation. Here’s a step-by-step guide to wiring your Bodine BSL17C C2:

Step 1: Identify the Key Components

Before you begin wiring your Bodine BSL17C C2, it’s important to identify the key components of the unit. These include:

Component Description
Battery The rechargeable battery that powers the emergency lighting.
Transformer The device that steps down the voltage from the building’s power supply to the voltage required by the Bodine BSL17C C2.
AC Input The power input for the transformer.
DC Output The power output for the Bodine BSL17C C2.
Load The emergency lighting that is powered by the Bodine BSL17C C2.

Step 2: Connect the AC Input

The AC Input should be connected to the building’s power supply. This can be done using a standard electrical outlet or by connecting directly to the building’s electrical system. The AC Input wires should be connected to the transformer’s AC input terminals.

Step 3: Connect the Transformer

The transformer should be connected between the AC Input and the DC Output. The transformer’s output wires should be connected to the Bodine BSL17C C2’s DC input terminals.

Step 4: Connect the Battery

The battery should be connected to the Bodine BSL17C C2’s battery terminals. The battery is typically shipped with the unit and may need to be installed before wiring can begin.

Step 5: Connect the Load

The load, or emergency lighting, should be connected to the Bodine BSL17C C2’s output terminals. This can be done using standard wiring and should be connected in accordance with local building codes.

Frequently Asked Questions

What type of battery does the Bodine BSL17C C2 use?

The Bodine BSL17C C2 uses a sealed lead acid battery. This type of battery is rechargeable and typically lasts for 3-5 years before needing to be replaced.

How long does the Bodine BSL17C C2 provide emergency lighting?

The Bodine BSL17C C2 is designed to provide up to 90 minutes of emergency lighting in the event of a power outage.

Can the Bodine BSL17C C2 be used in outdoor applications?

The Bodine BSL17C C2 is designed for indoor use only and should not be used in outdoor applications.

What is the warranty on the Bodine BSL17C C2?

The Bodine BSL17C C2 comes with a 5-year warranty from the date of purchase. This warranty covers defects in materials and workmanship.

Is professional installation required for the Bodine BSL17C C2?

While professional installation is not required for the Bodine BSL17C C2, it is highly recommended to ensure that the unit is wired correctly and will function as intended in an emergency situation.

By following the wiring diagram provided by the manufacturer and using the information provided in this article, you can ensure that your Bodine BSL17C C2 is wired correctly and will provide reliable emergency lighting when you need it. Always consult local building codes and regulations when installing any electrical equipment.