Aiphone JO Series Wiring Diagram: Your Ultimate Guide

If you are looking for a reliable and easy-to-use intercom system for your home or business, the Aiphone JO series is an ideal choice. It provides crystal clear audio and video communication, allowing you to control entry and monitor your property from a single master station. However, the installation process can be daunting, especially if you don’t have a clear understanding of the wiring diagram. In this article, we will guide you through the Aiphone JO series wiring diagram in simple and easy-to-understand language.

What is the Aiphone JO Series?

The Aiphone JO series is a high-quality intercom system that allows communication between the master station and up to two sub-stations. It is ideal for residential and small business applications where security and communication are a priority. The system comes with a variety of features, including door release, video monitoring, and a touchscreen interface for easy control. However, to enjoy all these features, you need to understand how to wire the Aiphone JO series system correctly.

Wiring the Aiphone JO Series system

The Aiphone JO series wiring diagram is relatively simple, and with a little bit of guidance, you should be able to complete the installation without any major issues. Let’s take a look at the wiring diagram step-by-step.

Step 1: Understanding the components of the Aiphone JO Series system

Before we can start wiring the system, it’s essential to understand the various components that come with the Aiphone JO series. These include the master station, sub-stations, power supply, and door release. The master station is the main control unit that allows you to communicate with the sub-stations and control the various features of the system. The sub-stations are the secondary control units that allow communication between the master station and the door station. The power supply provides power to the entire system, while the door release is used to unlock the door remotely.

Step 2: Choosing the right wiring

The Aiphone JO series wiring diagram requires the use of specific wiring to ensure that the system works as intended. The recommended wiring is an 18AWG two-conductor non-shielded cable, which provides sufficient power and signal transmission between the master station and the sub-stations. It’s important to follow this recommendation to avoid any issues with the system’s performance.

Step 3: Wiring the power supply

The first step in wiring the Aiphone JO series system is to connect the power supply to the master station. The power supply should be connected to an AC outlet and then connected to the master station using the wiring diagram provided by Aiphone. The power supply provides power to the entire system, so it’s essential to ensure that it’s wired correctly.

Step 4: Wiring the master station

The next step is to wire the master station. The wiring diagram for the master station is relatively simple and requires connecting the two-conductor cable to the appropriate terminals on the master station. The wiring diagram provided by Aiphone shows how to connect the power, video, and audio cables to the master station.

Step 5: Wiring the sub-stations

The final step is to wire the sub-stations. The wiring diagram for the sub-stations is very similar to that of the master station, and it requires connecting the two-conductor cable to the appropriate terminals on the sub-station. The wiring diagram provided by Aiphone shows how to connect the power, video, and audio cables to the sub-station. It’s important to ensure that the sub-stations are wired correctly to avoid any issues with the system’s performance.

FAQ: Frequently asked questions about the Aiphone JO Series system wiring diagram

Question Answer
What type of wiring should I use for the Aiphone JO Series system? The recommended wiring is an 18AWG two-conductor non-shielded cable.
Can I wire the system myself or do I need to hire a professional? You can wire the system yourself if you have a basic understanding of electrical wiring. However, if you are not comfortable with the process, it’s recommended that you hire a professional to do it for you.
What is the maximum distance between the master station and sub-stations? The maximum recommended distance is 980 feet.
How many sub-stations can I connect to the Aiphone JO Series system? You can connect up to two sub-stations to the system.
What is the door release feature, and how does it work? The door release feature allows you to unlock the door remotely using the master station or sub-stations. It works by sending a signal from the master station to the door release component, which unlocks the door.

Conclusion

The Aiphone JO series is an excellent intercom system that provides crystal clear audio and video communication, allowing you to control entry and monitor your property from a single master station. However, it’s essential to understand how to wire the system correctly to avoid any issues with the system’s performance. By following the wiring diagram provided by Aiphone and our guide, you should be able to install the system without any major problems. If you have any questions or concerns, don’t hesitate to contact Aiphone’s support team for assistance.