320 Amp Meter Base Wiring Diagram

A 320 amp meter base is a large electrical component that is used to measure the amount of electricity that is consumed by a building. The meter base is typically mounted on the exterior of the building and is connected to the utility company’s power grid. This article will provide a wiring diagram for a 320 amp meter base and answer some frequently asked questions.

Overview of the Wiring Diagram

The wiring diagram for a 320 amp meter base is relatively simple. There are two sets of wires that need to be connected to the base: the line wires and the load wires. The line wires are the wires that come from the utility company’s power grid, and the load wires are the wires that go to the building’s electrical panel. The diagram is as follows:

Wire Color Connection
Line 1 Black Connects to Line 1 on the meter base
Line 2 Red Connects to Line 2 on the meter base
Neutral White Connects to the Neutral bar on the meter base
Ground Green or Bare Connects to the Ground bar on the meter base
Load 1 Black Connects to Load 1 on the meter base
Load 2 Red Connects to Load 2 on the meter base

FAQ

What size wire is needed for a 320 amp meter base?

The size of the wire that is needed for a 320 amp meter base depends on the length of the wire run and the load that it will be carrying. In most cases, 4/0 or 350 kcmil wire is recommended for the line wires, and 2/0 or 250 kcmil wire is recommended for the load wires. However, it is important to consult with a licensed electrician to determine the appropriate wire size for your specific installation.

Does the meter base need to be grounded?

Yes, the meter base needs to be grounded. The ground wire should be connected to the ground bar on the meter base, and the other end should be connected to the building’s grounding system. This will protect the building and its occupants from electrical shocks and other hazards.

Can a 320 amp meter base be used for a residential installation?

Yes, a 320 amp meter base can be used for a residential installation, but it is typically only necessary for large homes or multi-unit dwellings. Most residential installations only require a 100 or 200 amp service, which can be accommodated by a smaller meter base.

What is the lifespan of a 320 amp meter base?

The lifespan of a 320 amp meter base depends on several factors, including the quality of the installation, the environment in which it is located, and the amount of usage it receives. In general, a well-installed and well-maintained meter base should last for many years. However, it is important to have the meter base inspected periodically by a licensed electrician to ensure that it is functioning properly.

Who is responsible for maintaining the meter base?

The meter base is owned by the utility company, but the property owner is responsible for maintaining it. This includes keeping it clean and free from debris, ensuring that it is properly grounded, and having it inspected periodically by a licensed electrician. If there are any issues with the meter base, the property owner should contact the utility company to report them.

Conclusion

A 320 amp meter base is an important component of any electrical system, and it is crucial that it is installed and maintained properly. By following the wiring diagram and consulting with a licensed electrician, property owners can ensure that their meter base is functioning safely and efficiently. If you have any questions or concerns about your meter base, don’t hesitate to reach out to a professional for assistance.