Understanding the 1762 OW16 Wiring Diagram

If you’re looking to install or troubleshoot a 1762 OW16 module, understanding its wiring diagram is crucial. The 1762 OW16 is a digital output module that provides 16 output channels, each capable of switching up to 24V DC voltage. In this article, we’ll take a closer look at the wiring diagram for the 1762 OW16 module, and provide some FAQs to help you along the way.

1762 OW16 Wiring Diagram Overview

The 1762 OW16 wiring diagram consists of 16 output channels and a power input. Each output channel has two terminals, labeled “+” and “-” respectively. The “+” terminal is where the DC voltage is applied to activate the output channel, while the “-” terminal is for the ground connection.

The power input also consists of two terminals, labeled “L+” and “L-“. The “L+” terminal is where the positive voltage supply is connected, while the “L-” terminal is for the negative voltage supply. The 1762 OW16 module requires a voltage supply of 10 to 30V DC.

It’s important to note that the 1762 OW16 module is designed for use with common-cathode devices. This means that the “-” terminal of each output channel is connected to the common ground, while the “+” terminal is connected to the device to be controlled.

1762 OW16 Wiring FAQ

What is the maximum current rating for the 1762 OW16 module?

The maximum current rating for the 1762 OW16 module is 500mA per channel, with a total maximum current of 8A for the entire module.

What is the input impedance for the 1762 OW16 module?

The input impedance for the 1762 OW16 module is approximately 5k ohms.

What is the maximum cable length for the 1762 OW16 module?

The maximum cable length for the 1762 OW16 module depends on the cable gauge and ambient temperature. For example, using 24AWG cable at 25°C, the maximum cable length is approximately 285 meters (936 feet).

Can the 1762 OW16 module be used for pulse output applications?

Yes, the 1762 OW16 module can be used for pulse output applications. However, you should take care to ensure that the pulse frequency and duty cycle do not exceed the module’s specifications.

Can the 1762 OW16 module be used with AC voltage?

No, the 1762 OW16 module is designed for use with DC voltage only.

Conclusion

The 1762 OW16 wiring diagram provides a clear picture of how the module is wired and how it operates. Understanding this wiring diagram is essential for installing and troubleshooting the module. We hope this article has been helpful in providing a better understanding of the 1762 OW16 module and its wiring diagram.

Terminal Description
+ Output channel positive terminal
Output channel negative (ground) terminal
L+ Positive voltage supply terminal
L- Negative voltage supply terminal