Altronix ACM8 is a versatile and reliable access control power supply that provides power to various devices such as magnetic locks, electric strikes, and readers. The wiring diagram of ACM8 might seem confusing, but it is easy to understand if you have proper guidance.
Understanding the Wiring Diagram Components
Before we dive into the Altronix ACM8 wiring diagram, it is essential to know the wiring diagram’s critical components. The following are the key components of ACM8 wiring diagram:
- Power input
- AC fail output
- Output relays
- Control input
- Battery input/output
- Accessory output
Power Input
The power input is where you connect the AC power source coming from the mainline. In the case of ACM8, you can connect either 115VAC or 230VAC power sources.
AC Fail Output
The AC fail output is intended to alert you when the input power fails. It is an essential feature because it ensures you have an immediate response to power loss, preventing any data losses or system failures.
Output Relays
The output relays determine the amount of power output to devices such as electric strikes, magnetic locks, and other access control devices. There are eight output relays in ACM8, and each has a 5A capacity.
Control Input
The control input allows you to control the power output through various means such as tamper switches and fire alarms. It ensures that the access control system remains safe and secure in case of any emergencies that require immediate response.
Battery Input/Output
The battery input/output is where you connect an external battery source to act as a backup in case of power failure. The battery input and output allow the system to continue running, ensuring there is no data loss or system failure.
Accessory Output
The accessory output allows you to connect various devices such as motion detectors and exit buttons to control the access control system.
Altronix ACM8 Wiring Diagram
The Altronix ACM8 wiring diagram might seem complicated, but it is easy to understand if you have proper guidance. The following is a comprehensive guide to the ACM8 wiring diagram:
Terminal | Wire Color | Description |
---|---|---|
1 | Black | 115VAC input |
2 | Blue | Neutral |
3 | Orange | GND |
4 | Green | AC fail output |
5-12 | Red | Output relays |
13 | White | Control input |
14 | Yellow | Battery input/output |
15 | Purple | Accessory output |
The wiring diagram’s terminals are numbered in a clockwise direction, starting from the top left corner.
Connecting Power Input
Connect the power input wires to terminals 1 (black), 2 (blue), and 3 (orange). Ensure that the AC power source’s voltage matches the voltage specified on the ACM8 device.
Connecting AC Fail Output
The AC fail output wire (green) can be connected to either terminal 4 or 13 depending on your preference. If you connect it to terminal 4, it will provide a normally closed output, and if you connect it to terminal 13, it will provide a normally open output.
Connecting Output Relays
The output relays wires (red) are connected to terminals 5-12. Each terminal connects to a different output relay, and it is recommended to label each wire to match the device it connects to.
Connecting Control Input
The control input wire (white) can be connected to either terminal 4 or 13 depending on your preference. If you connect it to terminal 4, it will provide a normally closed input, and if you connect it to terminal 13, it will provide a normally open input.
Connecting Battery Input/Output
The battery input/output wire (yellow) is where you connect the external battery source. It is essential to ensure that the battery voltage matches the voltage specified on the ACM8 device.
Connecting Accessory Output
The accessory output wire (purple) provides a 12VDC output that can be used to power various devices such as motion detectors and exit buttons.
FAQs
What is the maximum current capacity of the output relays?
The output relays on ACM8 have a maximum current capacity of 5A per relay.
Can I connect multiple devices to one output relay?
No, it is not recommended to connect multiple devices to one output relay. Doing so may exceed the maximum current capacity, which can lead to device failure or system damage.
What happens when the AC power source fails?
If the AC power source fails, the AC fail output wire (green) will provide a signal that can be connected to an alarm or security system, alerting you of the power loss.
What is the purpose of the battery input/output?
The battery input/output provides a backup power source in case of an AC power failure. It ensures that the access control system remains operational, preventing any data loss or system failures.
Can I use ACM8 with both 115VAC and 230VAC power sources?
Yes, ACM8 is designed to work with both 115VAC and 230VAC power sources. Ensure that the voltage matches the specification on the device.
Can I use ACM8 with any access control devices?
Yes, ACM8 is compatible with various access control devices such as magnetic locks, electric strikes, and readers. However, it is essential to ensure that the devices’ voltage and current ratings match the specifications on the ACM8 device.
Conclusion
The Altronix ACM8 wiring diagram might seem confusing at first, but it is easy to understand if you have proper guidance. The wiring diagram’s critical components include power input, AC fail output, output relays, control input, battery input/output, and accessory output. By following the guidance on this article, you can properly connect ACM8 to various access control devices, ensuring they remain operational at all times.