Allen Bradley 700 HR52TA17 Wiring Diagram: A Comprehensive Guide

The Allen Bradley 700 HR52TA17 is a relay time delay module that is designed to provide timing functions in industrial control systems. This module is widely used in machinery, automation, and other industrial applications, and its wiring diagram is a critical component that needs to be understood by technicians and engineers who work on these systems. In this article, we will provide a detailed guide to the Allen Bradley 700 HR52TA17 wiring diagram, its components, installation, and FAQ.

Overview of the Allen Bradley 700 HR52TA17 Wiring Diagram

The Allen Bradley 700 HR52TA17 wiring diagram provides a visual representation of the connections and components that make up the module. The wiring diagram consists of several parts, including the power supply, control inputs, timing functions, and output contacts. Each part is labeled with a specific code or symbol, which helps in identifying its function and location in the circuit.

Power Supply

The power supply is the first component in the Allen Bradley 700 HR52TA17 wiring diagram. This module requires a voltage of 24 VDC to operate. The power supply connects to terminals 10 and 11 in the module. These terminals are labeled as (+) and (-), respectively. The power supply provides the necessary power to activate the module and its timing functions.

Control Inputs

The control inputs are the next components in the wiring diagram. The module has two control inputs that are labeled as terminals 5 and 6. These inputs are used to trigger the timing functions of the module. When a signal is applied to the control inputs, the module starts counting and activates the output contacts when the preset time is reached.

The control inputs can be either a momentary or sustained signal. A momentary signal lasts only for a brief period, while a sustained signal persists for a longer duration. To connect a momentary signal, connect it to terminal 5, and connect terminal 6 to the ground. To connect a sustained signal, connect it to both terminals 5 and 6.

Timing Functions

The timing functions are the core components of the Allen Bradley 700 HR52TA17 wiring diagram. These functions determine how long the module will take to activate the output contacts after receiving a signal from the control inputs. The module has several timing functions that can be adjusted according to the requirements of the application.

The timing functions of the Allen Bradley 700 HR52TA17 module can be adjusted using the time delay potentiometer. This component is connected to terminal 9 and is used to set the duration of the timing functions. The potentiometer can be adjusted using a screwdriver, and the duration can be adjusted in a range of a few seconds to several minutes.

Output Contacts

The output contacts are the final components in the Allen Bradley 700 HR52TA17 wiring diagram. The output contacts provide a signal to control other components in the circuit. The module has two output contacts labeled as terminals 7 and 8. These contacts are normally open, which means that they do not conduct electricity when the module is not activated. When the module is activated, the contacts close and conduct electricity.

The output contacts can be used to activate a motor, a solenoid, or any other component that requires a timed signal. To connect the output contacts, connect terminal 7 to the positive side of the load, and connect terminal 8 to the negative side of the load.

FAQ

1. What is the Allen Bradley 700 HR52TA17 module used for?

The Allen Bradley 700 HR52TA17 module is a relay time delay module that is used in industrial control systems to provide timing functions. This module is widely used in machinery, automation, and other industrial applications.

2. What is the power supply requirement for the Allen Bradley 700 HR52TA17 module?

The Allen Bradley 700 HR52TA17 module requires a voltage of 24 VDC to operate. The power supply connects to terminals 10 and 11 in the module. These terminals are labeled as (+) and (-), respectively.

3. How many control inputs does the Allen Bradley 700 HR52TA17 module have?

The Allen Bradley 700 HR52TA17 module has two control inputs that are labeled as terminals 5 and 6. These inputs are used to trigger the timing functions of the module.

4. How are the timing functions of the Allen Bradley 700 HR52TA17 module adjusted?

The timing functions of the Allen Bradley 700 HR52TA17 module can be adjusted using the time delay potentiometer. This component is connected to terminal 9 and is used to set the duration of the timing functions. The potentiometer can be adjusted using a screwdriver, and the duration can be adjusted in a range of a few seconds to several minutes.

5. What are the output contacts of the Allen Bradley 700 HR52TA17 module used for?

The output contacts of the Allen Bradley 700 HR52TA17 module provide a signal to control other components in the circuit. The module has two output contacts labeled as terminals 7 and 8. These contacts are normally open, which means that they do not conduct electricity when the module is not activated. When the module is activated, the contacts close and conduct electricity.

Conclusion

The Allen Bradley 700 HR52TA17 wiring diagram is a critical component that needs to be understood by technicians and engineers who work on industrial control systems. This module provides timing functions that are essential for the automation and operation of machinery and other industrial applications. By understanding the wiring diagram, technicians and engineers can troubleshoot and diagnose problems in the module, ensure proper installation, and optimize its performance.