700 hr52ta17 Wiring Diagram

If you are installing a 700 hr52ta17 timing relay in your electrical system, it is important to have a clear understanding of the wiring diagram. This article will provide a detailed guide on the wiring diagram for the 700 hr52ta17 timing relay, including tables and FAQs.

Overview of 700 hr52ta17 Timing Relay

The 700 hr52ta17 timing relay is a device used in electrical systems to control time-delayed switching sequences. With this relay, you can set a specific time delay for the switching of devices in your electrical system, which makes it very useful in automation applications.

The device comes with a wiring diagram that is crucial to the installation process. The wiring diagram shows how the electrical connections should be made, making it easy for you to install the device correctly.

Wiring Diagram for 700 hr52ta17

The wiring diagram for the 700 hr52ta17 timing relay is fairly straightforward. It consists of four main components: input voltage terminals, output voltage terminals, time delay setting, and adjustment knob. The wiring diagram is as follows:

Terminal Connection
1 Input voltage: 110-240V AC/DC
2 Input voltage: 110-240V AC/DC
3 NC output: 250V AC/DC, 5A
4 NO output: 250V AC/DC, 5A
5 COM output: 250V AC/DC, 5A
6 Time delay setting: 0-700 hours
7 Adjustment knob: Time delay adjustment

As seen in the table above, terminals 1 and 2 are for input voltage, while terminals 3, 4, and 5 are for the output voltage. Terminal 6 is for time delay setting, and terminal 7 is for adjusting the time delay.

Wiring Procedure

The following is a step-by-step guide on how to wire the 700 hr52ta17 timing relay:

Step 1: Switch off power

Before you begin wiring, ensure that the power to the electrical system is switched off to prevent accidents or damage to the device.

Step 2: Connect input voltage

Connect the input voltage to terminals 1 and 2 of the device, ensuring that the voltage is within the recommended range (110-240V AC/DC).

Step 3: Connect output voltage

Connect the output voltage to terminals 3, 4, and 5 of the device. Ensure that the correct polarity is observed.

Step 4: Set time delay

Set the time delay using terminal 6. The time delay can be set anywhere between 0-700 hours.

Step 5: Adjust time delay

Adjust the time delay using terminal 7. This adjustment can be made after the time delay has been set.

Step 6: Switch on power

Once you have completed wiring, switch on the power to the electrical system and test the device to ensure that it is working correctly.

FAQ

1. What is the voltage range for the 700 hr52ta17 timing relay?

The voltage range for the 700 hr52ta17 timing relay is 110-240V AC/DC.

2. What is the maximum time delay that can be set with the 700 hr52ta17?

The maximum time delay that can be set with the 700 hr52ta17 is 700 hours.

3. What is the output voltage range for the 700 hr52ta17 timing relay?

The output voltage range for the 700 hr52ta17 timing relay is 250V AC/DC, 5A.

4. Can I adjust the time delay after it has been set?

Yes, you can adjust the time delay after it has been set using terminal 7.

5. How do I connect the output voltage?

The output voltage should be connected to terminals 3, 4, and 5 of the device. Ensure that the correct polarity is observed.

Conclusion

The 700 hr52ta17 timing relay is an essential device for controlling time-delayed switching sequences in electrical systems. Understanding the wiring diagram is crucial to the successful installation of the device. With the guide provided in this article, you should be able to wire the device correctly and get it up and running in your system.