Understanding the 8145 20B Wiring Diagram

Have you been struggling with understanding the 8145 20B wiring diagram? Look no further as we break down everything you need to know in this comprehensive guide.

What is the 8145 20B Wiring Diagram?

The 8145 20B is a defrost timer used in commercial refrigeration applications. The wiring diagram is a visual representation of how the different components are connected to each other in the defrost timer.

Understanding the wiring diagram is crucial in troubleshooting any issues that may arise with the defrost timer.

The Basics of the Wiring Diagram

Before we dive into the specifics of the wiring diagram, let’s go over the basics of how it works. The 8145 20B defrost timer has four terminals labeled 1, 2, 3, and 4. Terminals 1 and 2 are for power, while terminals 3 and 4 are for the defrost heater.

The timer motor inside the defrost timer is powered by terminals 1 and 2, which allows it to keep track of time. When it’s time for the defrost cycle to start, the timer sends power to the defrost heater through terminals 3 and 4.

Decoding the Wiring Diagram

Now that we understand the basics, let’s take a closer look at the wiring diagram.

Terminal Color Code Function
1 Black Power In
2 White Power In
3 Red Defrost Heater Out
4 Blue Defrost Heater Out

The table above shows the color code and function of each terminal in the 8145 20B defrost timer.

Terminal 1

The black wire is connected to terminal 1 and is used to provide power to the defrost timer. This wire is usually connected to a circuit breaker or fuse.

It’s important to make sure that the circuit breaker or fuse is the correct size or amperage rating for the defrost timer. Using the wrong size can cause the defrost timer to malfunction or fail altogether.

Terminal 2

The white wire is connected to terminal 2 and is also used to provide power to the defrost timer. This wire is usually connected to a neutral or ground wire.

Again, it’s important to make sure that the wiring is correct and the circuit breaker or fuse is the correct size.

Terminal 3

The red wire is connected to terminal 3 and is used to provide power to the defrost heater during the defrost cycle. This wire is usually connected to the defrost heater.

Make sure that the defrost heater is the correct size and type for the application. Using the wrong heater can cause the system to malfunction or fail.

Terminal 4

The blue wire is connected to terminal 4 and is also used to provide power to the defrost heater during the defrost cycle. This wire is also usually connected to the defrost heater.

Frequently Asked Questions

What happens if the wiring is incorrect?

If the wiring is incorrect, the defrost timer may not function properly. This can lead to issues such as the defrost cycle not starting or not stopping.

How do I troubleshoot issues with the defrost timer?

If you’re experiencing issues with the defrost timer, start by checking the wiring to make sure it’s correct. You can also check the defrost timer using a multimeter to ensure that it’s sending power to the defrost heater at the right time.

What is the lifespan of the defrost timer?

The lifespan of the defrost timer depends on a variety of factors such as the application, usage, and environment. Generally, they can last anywhere from five to ten years with proper maintenance and care.

Can I install the defrost timer myself?

It’s recommended that you hire a licensed professional to install the defrost timer. They have the knowledge and experience to ensure that the wiring and installation is done correctly to avoid any issues or safety hazards.

Conclusion

Understanding the 8145 20B wiring diagram is crucial in troubleshooting any issues that may arise with the defrost timer. By following the basics and decoding the wiring diagram, you can avoid any potential issues and ensure that the defrost timer is functioning properly.

Remember to always seek professional help if you’re unsure about any part of the installation or troubleshooting process.