3 Phase CT Meter Wiring Diagrams

When it comes to electrical installations and measurements, accuracy is important. One tool that electricians use to measure current is the current transformer (CT). A 3 phase CT meter is a device that uses CT to measure the amount of electrical energy consumed by a three-phase circuit. In this article, we’ll discuss the wiring diagrams for 3 phase CT meters, including the different types of connections that can be used, and the importance of accurate wiring.

Types of 3 Phase CT Meter Connections

There are generally three types of 3 phase CT meter connections. These are the three-wire connection, the four-wire delta connection, and the four-wire wye connection. Each of these connections has its own wiring diagram, which will be discussed below.

Three-Wire Connection

A three-wire 3 phase CT meter connection, also known as a two-element connection, is used when there is no neutral wire in the three-phase circuit. In this connection, the CTs are connected to the three phase wires, and the current is measured across two of the three wires. The wiring diagram for a three-wire connection is shown in Table 1.

CT Terminal Connection
X1 Line 1
X2 Line 2
X3 Line 3

Table 1: Wiring diagram for a three-wire 3 phase CT meter connection

It’s important to note that in a three-wire connection, the CTs must be installed in the correct phase sequence. This means that the CT installed on line 2 must be installed in the opposite direction to the CTs installed on lines 1 and 3. This ensures that the current is measured correctly.

Four-Wire Delta Connection

A four-wire delta connection is used when there is a neutral wire in the three-phase circuit. In this connection, the CTs are connected to the three phase wires and the neutral wire, and the current is measured across the three phase wires. The wiring diagram for a four-wire delta connection is shown in Table 2.

CT Terminal Connection
X1 Line 1
X2 Line 2
X3 Line 3
X4 Neutral

Table 2: Wiring diagram for a four-wire delta connection

It’s important to note that in a four-wire delta connection, the neutral wire is not used to measure the current. The neutral wire is only used to provide a reference point for the voltage measurements.

Four-Wire Wye Connection

A four-wire wye connection is used when there is no neutral wire in the three-phase circuit, but a neutral connection is required for the load. In this connection, the CTs are connected to the three phase wires, and the neutral wire is connected to a separate terminal on the CT. The wiring diagram for a four-wire wye connection is shown in Table 3.

CT Terminal Connection
X1 Line 1
X2 Line 2
X3 Line 3
X0 Neutral

Table 3: Wiring diagram for a four-wire wye connection

It’s important to note that in a four-wire wye connection, the neutral wire is used to measure the current. This means that the CT installed on the neutral wire must be installed in the same direction as the CTs installed on the phase wires.

FAQs

What is a CT meter?

A CT meter is a device that uses current transformers to measure the amount of electrical energy consumed by a circuit. It is commonly used in three-phase circuits where accurate measurement of current is required.

What is the purpose of a CT?

The purpose of a CT is to measure the amount of current flowing through a circuit. It is commonly used in electrical installations to provide an accurate measurement of current, which is required for billing purposes and to ensure that the circuit is operating within safe limits.

Why is accurate wiring of a CT meter important?

Accurate wiring of a CT meter is important to ensure that the current is measured correctly. Incorrect wiring can result in inaccurate measurements, which can lead to incorrect billing and potentially dangerous situations if the circuit is operating outside safe limits.

What are the different types of 3 phase CT meter connections?

The three types of 3 phase CT meter connections are the three-wire connection, the four-wire delta connection, and the four-wire wye connection. Each of these connections has its own wiring diagram, which is important to follow to ensure accurate measurement of current.

Can a CT be used to measure voltage?

No, a CT cannot be used to measure voltage. CTs are designed to measure current only. To measure voltage, a voltage transformer (VT) must be used.