2707a L Wiring Diagram

If you are looking for a wiring diagram for the 2707a L, you have come to the right place. This device is used in a variety of applications, and understanding the wiring is essential for proper installation and operation.

What is the 2707a L?

The 2707a L is a temperature controller manufactured by Eurotherm. It is designed to measure and control temperature in a variety of industrial applications. It is a versatile device that can be used in many different settings, ranging from food processing to chemical manufacturing.

The 2707a L is designed to be user-friendly, with intuitive controls and a clear display. It is also highly customizable, with a range of options and settings that can be adjusted to meet the needs of different applications.

Wiring Diagram Overview

The wiring diagram for the 2707a L consists of several components, including the power supply, input, output, and communication ports. Each component is connected using specific wires and terminals.

The input section of the wiring diagram consists of three wires, which are used to connect the temperature sensor to the controller. The output section of the diagram consists of two wires, which are used to connect the controller to the heating, cooling, or alarm devices.

There are also several communication ports on the 2707a L, which can be used to connect the device to a computer or network. These ports are typically used for remote monitoring and control.

Wiring Diagram Details

Power Supply

The power supply section of the wiring diagram includes two terminals: L1 and N. L1 is the live wire, while N is the neutral wire. These wires are used to connect the controller to the electrical supply.

It is important to note that the 2707a L requires a stable power supply, with a voltage range of 85-264 VAC. If the voltage supply is unstable, it can cause the controller to malfunction or even fail.

Input

The input section of the wiring diagram includes three terminals: T+ and T- for the temperature sensor, and C for the cold junction compensation. These terminals are used to connect the temperature sensor to the controller.

The temperature sensor can be either a thermocouple or a resistance temperature detector (RTD). The wiring for each type of sensor is slightly different, but in general, the T+ wire is connected to the positive terminal of the sensor, while the T- wire is connected to the negative terminal of the sensor.

The C terminal is used to connect the cold junction compensation circuit, which is used to compensate for temperature variations in the wiring between the sensor and the controller.

Output

The output section of the wiring diagram includes two terminals: H and L. These terminals are used to connect the controller to the heating, cooling, or alarm devices.

The H terminal is connected to the positive terminal of the device, while the L terminal is connected to the negative terminal. The type of device that is connected to the controller depends on the application. For example, in a heating application, the device may be a heater coil or a heating element.

Communication Ports

The 2707a L has several communication ports, which can be used to connect the device to a computer or network. These ports include RS232, RS485, and Ethernet ports.

The RS232 port is a standard serial port that can be used to connect the controller to a computer or other device. The RS485 port is a serial port that is used for communication between multiple devices, such as in a network. The Ethernet port is used to connect the controller to a local area network (LAN) or wide area network (WAN).

FAQs

What is the maximum voltage that can be used with the 2707a L?

The 2707a L is designed to work with a voltage range of 85-264 VAC. It is important to use a stable power supply within this range, to ensure proper operation and prevent damage to the controller.

What type of sensors can be used with the 2707a L?

The 2707a L can be used with both thermocouples and resistance temperature detectors (RTDs). The type of sensor that is used depends on the application and the temperature range that is being measured.

Can the 2707a L be used for remote monitoring and control?

Yes, the 2707a L has several communication ports that can be used for remote monitoring and control. These ports include RS232, RS485, and Ethernet ports.

What type of devices can be connected to the output terminals of the 2707a L?

The type of device that is connected to the output terminals of the 2707a L depends on the application. In a heating application, the device may be a heater coil or a heating element. In a cooling application, the device may be a refrigeration system or cooling fan. In an alarm application, the device may be a warning light or siren.

Conclusion

The wiring diagram for the 2707a L is an essential tool for proper installation and operation of this versatile temperature controller. Understanding the different components and their connections is key to ensuring that the device is functioning properly and safely.

If you have any questions about the wiring diagram or the 2707a L in general, please refer to the user manual or contact the manufacturer for assistance.