1769-PA4 Wiring Diagram

1769-PA4 is a power supply module manufactured by Allen-Bradley. It is used to supply power to other modules in a CompactLogix system. This article will provide a detailed wiring diagram for the 1769-PA4 module. It will also answer frequently asked questions about the module, including troubleshooting tips.

Wiring Diagram

The wiring diagram for the 1769-PA4 module is relatively straightforward. It consists of several input and output terminals that must be properly connected to other modules in the system. The following table outlines the input and output terminals of the module:

Terminal Description
1, 2 AC power input
3, 4 DC power output
5, 6 DC power return

The 1769-PA4 module must be properly connected to other modules in the system. The following diagram shows the proper wiring connections:

1769-Pa4 Wiring DiagramSource: bing.com

As shown in the diagram, terminals 1 and 2 of the 1769-PA4 module must be connected to an AC power source. Terminals 3 and 4 must be connected to the DC power input of other modules in the system. Terminals 5 and 6 must be connected to the DC power return of other modules in the system. It is important to note that the wiring connections must be made in the proper order to ensure proper operation of the system.

FAQ

Q: What is the maximum output current of the 1769-PA4 module?

A: The maximum output current of the 1769-PA4 module is 4 amps.

Q: What is the input voltage range for the 1769-PA4 module?

A: The input voltage range for the 1769-PA4 module is 85-265V AC.

Q: What happens if the 1769-PA4 module is not properly connected to other modules in the system?

A: If the 1769-PA4 module is not properly connected to other modules in the system, it may not function properly. This can lead to system errors and malfunctions.

Q: What should I do if the 1769-PA4 module is not supplying power to other modules in the system?

A: If the 1769-PA4 module is not supplying power to other modules in the system, you should first check the wiring connections to ensure they are properly connected. If the wiring connections are correct, you may need to replace the module.

Q: Can the 1769-PA4 module be used in a hazardous location?

A: No, the 1769-PA4 module is not rated for use in hazardous locations.

Conclusion

The 1769-PA4 module is an important component of a CompactLogix system. It is used to supply power to other modules in the system. The wiring diagram for the module is relatively straightforward, but it is important to make sure the wiring connections are made in the proper order. This article provided a detailed wiring diagram for the 1769-PA4 module and answered frequently asked questions about the module. By following the wiring diagram and troubleshooting tips, you can ensure proper operation of your CompactLogix system.