1746 ox8 Wiring Diagram

If you are looking for a reliable wiring diagram for your 1746 ox8 module, then you have come to the right place. In this article, we will discuss the various aspects of wiring the 1746 ox8 module and provide you with detailed information and guidance that will help you successfully wire your module in no time.

What is the 1746 ox8 module?

The 1746 ox8 module is an 8-channel analog output module that is designed to provide high-quality analog signals for your industrial applications. This module can be used to control various industrial processes and can be integrated with your existing control system to provide accurate and reliable analog output signals.

The 1746 ox8 module is a part of the ControlLogix family of modules that are designed to provide exceptional performance and reliability to your industrial control system.

Module Specifications

The 1746 ox8 module has the following specifications:

Specification Description
Channels 8 channels
Output range ±10V DC
Resolution 16-bit
Update time 3ms/point

Wiring the 1746 ox8 module

The 1746 ox8 module is a relatively simple module to wire. The module has a removable terminal block that provides easy access to the channels and ground connections. The following steps will guide you through the process of wiring the 1746 ox8 module:

Step 1: Mount the module

The first step in wiring the 1746 ox8 module is to mount the module in your control cabinet. The module should be mounted on a DIN rail to ensure proper grounding and easy installation.

Step 2: Connect the power supply

The next step is to connect the power supply to the module. The module requires a 24V DC power supply that should be connected to the power terminal block on the module.

Step 3: Connect the analog output signals

The analog output signals should be connected to the module’s output terminal block. The module has eight output channels, each with its own terminal block. The output signals should be connected to the appropriate channel terminal block.

Step 4: Connect the ground connections

The ground connections should be connected to the module’s ground terminal block. The module has a separate ground terminal block for each channel. The ground connections should be connected to the appropriate channel ground terminal block.

Step 5: Verify the wiring

Once the wiring is complete, it is important to verify the wiring to ensure that all connections are secure and properly wired. This can be done by checking the wiring diagram provided with the module and using a multimeter to verify that the signals are correctly connected.

FAQ

What is the output range of the 1746 ox8 module?

The output range of the 1746 ox8 module is ±10V DC.

What is the resolution of the 1746 ox8 module?

The resolution of the 1746 ox8 module is 16-bit.

What is the update time of the 1746 ox8 module?

The update time of the 1746 ox8 module is 3ms/point.

How many channels does the 1746 ox8 module have?

The 1746 ox8 module has eight channels.

What is the power supply requirement for the 1746 ox8 module?

The 1746 ox8 module requires a 24V DC power supply.

Overall, the 1746 ox8 module is a reliable and high-quality analog output module that can be used to control various industrial processes. By following the above steps and guidelines, you can easily wire your 1746 ox8 module and start using it to control your industrial applications with ease.